Raised access floor - Jiangsu Eastchina Computer Room Group Co.,Ltd.

Raised access floor - Jiangsu Eastchina Computer Room Group Co.,Ltd.

All steel anti-static floor

In 1, the steel composition, high mechanical strength, strong bearing capacity, good impact resistance; 2, the surface electrostatic spray, soft, abrasion resistant, waterproof, fire prevention, dust-proof, anti-corrosion; 3, the affixed decorative high-pressure laminates, the wear resistance and anti static performance, resistance to pollution, easy cleaning, decorative and strong; in 4, high size precision, good interchangeability, flexible assembly, convenient repair, long service life; 5, the floor can be arbitrary cutting, convenient installation accessories; 6, four sides fixed, convenient installation; 7, the lower space can be used of air-conditioning ventilation, also can cooperate to regulate the ventilation ventilation plate; 8, for heavy equipment, as long as in the floor to increase the stent, can solve the bearing problem; 9, convenient disassembly and assembly, as long as the replacement of decorative veneer, can be repeated use; 10, install the outlet can be based on ground socket specifications for open hole. Scope: steel flooring anti-static load requirements and applicable in occasions with high requirements, such as large servers and mainframe cabinet room; large, medium and small computer room, to switch to represent communication center, electrical control rooms, post and telecommunications hub and using a computer to control the military, economic, national security, aviation, aerospace and transportation and information management command and dispatch center link.

...

Engine room floor

Engine room floor is also called dissipative static floor. When it is grounded or connected to any lower potential point, so that the charge dissipation, to resistance in 10 to the power of 5 to 10 between 9 ohms. Computer room of the anti-static technology, belong to the computer safety and protection areas part. Due to various reasons and the generation of static electricity, is the most frequently occurring, one of the most difficult to eliminate the hazards. Not only will on computer operation random failure, malfunction or operation errors, but also lead to some components, such as CMOS, MOS circuit, double stage of circuit breakdown and destruction. In addition to electrostatic on the external equipment of the computer also has apparent effect. With CRT display device, when subjected to static interference, will cause the image disorder, blur. Static electricity will cause Modem, Ethernet, Fax and other disorders, printer line is not smooth etc.. The problems caused by static electricity not only the hardware is very difficult to detect, sometimes software personnel mistaken for software fault, resulting in confusion. In addition, electrostatic through the body to a computer or other device to discharge (the so-called ignition ) when the energy reaches a certain level, also can give a person with feeling.

...

Movable floor profile

Movable floor, also known as the assembly type floor or false floor, its structure is sixty time initial stage the United States emerged, eighty time are our country is widely used in computer technology facilities. It is composed of various specifications and materials of the face plates, beams, adjustable bracket combination and assembly. Movable floor with grass ground or floor between the overhead space, can not only meet the laying of cables and pipelines arranged in a crisscross pattern needs, and through the design of overhead floor, in proper position setting vents, can also satisfy the static pressure air supply and air conditioning requirements.Maintenance measures in 1, a load is placed on the floor, should avoid heavy in the floor dragging, the contact surface is also should not be too small, can be used for dunnage planks must be. Weight caused by concentrated load is too large, should be at the stress points of strengthening with bracket. 2, walk on the floor or job, not wear shoes with metal studs, cannot use more sharp, hard objects on the floor surface and scratching and percussion. In order to ensure the floor cleaning, floor wax can be applied. When local contamination, use gasoline, alcohol or soap, detergent scrub.

...

Anti static floor design key points of selection

In 1, the activities of anti-static flooring fire rating, should conform to the" design of interior decoration of buildings" requirements. 2, anti-static movable floor height should be used according to required. (1 ) for walk the line: basic dimensions for 250mm. ( 2) for walk the line and the air conditioning wind Library: basic dimensions for 400mm. The floor of the detachable plate can interchange, and has high manufacturing precision, to ensure that the floor space as the air base when in use, the required sealing. 3, antistatic room floor paving construction is in the final stages of building decoration. In the indoor ceiling laying is completed, ceiling lamps, vents are installed, clean ground, paving floor activities (with insulation cotton and trough to spread good insulation cotton and slot ). 4, antistatic room floor is laid on the leveling cement mortar pad has, in order to reduce the height of ground approach, direct spread on the structure floor slab, slab structure requirements of surface roughness, and the interfacial agent is sprayed, uncured concrete surface, so that the ground sand can not afford. In 5, floor surface should be soft, not slipping, wear-resistant, resistant to pollution. In 6, the floor after installation must be grounded, or not to the anti-static effect.

...

The use of floor heating system needs to pay attention to the problem

1 selected as far as possible with the use of marble, tile or flooring. Such as the selection of wood floor, can only use of composite floor solid wood floor, can not be used. Wood flooring heat better stability, moisture content is low, so that the floor is not easy to deform after being heated; floor size should be thin thick, should narrow to wide, to resist deformation and transmission requirements; the floor under the mat is too thick, to facilitate heat exchange and transmission. Be sure to use harmful substances such as formaldehyde release quantity small floor, so that the floor by baking and release more pollution and harms your health.The 2 floor as far as possible not big area of ornaments ( such as carpet). No set of furniture without legs, so as not to reduce the effective radiating area and the hot air flow to cause the thermal effect weakened.The 3 floor is placed in ordinary foam and plastic products. Because these items are poor thermal conductivity, easy to cause the thermal aggregation, in long term under the heat is easy to produce harmful gases, endangering the health of occupants.4 open floor heating system to slow heating. Do not act with undue haste, one hour temperature 1 degrees celsius. In the warming up before a keep the floor clean and dry, to prevent the floor due to excessive heat distortion and cracking.5 do not drop, hitting the ground or on the ground. A into any sharp object. Laying on the ground under the floor heating floor heating cable surface only about 3-4cm, if not pay attention to easily cut the heating cable.6 water temperature should not be too high. As a result of floor heating system with low temperature radiation heating way belongs to, so for the heating cable is not more than 65 DEG C, heating system work pressure is high, otherwise, will not only cause heating problems of uncomfortable, serious will decrease the lifespan of the system.The 7 floor paving completed the best environmental protection acceptance. Because as a floor heating system floor composite floor, itself exist formaldehyde emission problems, while its as geothermal floor, after heating, more drama the release of formaldehyde. Therefore, the pavement ends geothermal heating floor, must do the acceptance of environmental protection, to ensure that the free formaldehyde emission standard. Can not buy cheap price of environmental protection, otherwise no end of trouble for the future!

...

Anti static floor enterprise how to promote the best results

How to use news media to publicize our corporate image and brand influence? Anti-static flooring products are required, how to let more people know your products.Use the news-advertisement promotion in the form of your company's anti-static flooring products, network marketing news, also known as network marketing, the use of the Internet technology, integration of domestic numerous websites advantages of resources, enterprises, brand, figure, products, events and other information related to news reports, timely, comprehensive, effective, economical to the public widely spread the new marketing way.Network news marketing as an effective means of promotion, gradually from the altar to the civilians, is no longer so far superior, and so. At the same time the malpractice also emerge as the times require: market confusion, dragons and fishes jumbled together. These 8 words to represent today's news network marketing. Price is uneven, some good and some bad, even a malicious competition; malicious competition resulted in a cost-effective speeding down, make the enterprise loses its faith; operator and the enterprise subjective generally believe that network news marketing simply issued a press release, the operator is positioned at the news of his own level, enterprise also only is the operator when press machine. This makes the enterprise and operator and misunderstanding, into an extreme." Marketing is not so smart way of selling their products and services, but also a real customer value creation of art." Because, marketing model is a system, rather than a means of this system, the comprehensive strength, deciding this brand sales level.

...

The floor exercise ( produces a sound ) for the following reasons

The floor exercise ( produces a sound ) for the following reasons:The 1 surface roughnessBecause the surface is not smooth, floor coverings, individual place between the floor and the ground to produce gap, people walk in the process, the floor move up and down, produces a sound. Its characteristic is the floor pavement after, people walking will immediately produce the sound, but also local. Measures are floor pavement before you must first measuring surface roughness, the flatness is less than 3mm / 2000mm, does not have the conditions of ground, should first leveling after the shop.The 2 floor decking surrounding presetting gap deficiencyFloor decking surrounding presetting gap leads to insufficient floor slightly arching. The floor and the ground clearance, people walking to produce sound. Its characteristic is just after the pavement is not noisy, after a period of time, a large area of ring wall and the floor has top, very tight. Take measures is the floor surrounding sufficient gap, especially the door, closet, balcony area such as domain have gaps, the gap is uniform to ensure the reservation. Pavement length than 8m should be separated off and the bridge processing.3 waterproof breathable membraneFloor decking, due to moisture film connection without using adhesive tape sealing, individual local moisture film in the paving process crashed, causing ground moisture leakage, especially geothermal environments, wet ground, large amounts of moisture from entering the back of floor, causing uneven expansion, so that the floor deformation, a slight twist, between the floor and the ground a gap is generated, in step step process to produce sound. The class is characterized by a rigid pavement is not sound, after a period of time to produce large noise, the wall and the floor may have gaps. Taking measures to apply is floor coverings, moisture-proof membrane joints must use the tape sealing, to ensure that no air.4 indoor furniture ( weight) of symmetrically placedFloor decking, because furniture and heavy items in the room sides symmetrically placed, to board are pressed, moisture in the environment condition, floor moisture absorption expansion, because both sides were heavy on floors, jumping, regional drum package. The area produces a sound board. Measures were taken to ensure weight on the side, one side of the floor by sports since. The floor of the sound is sometimes a factors, sometimes several kinds of elements are common the result of action. Therefore, to prevent pavement floor produces a sound, comprehensive measures should be taken to apply, comprehensive prevention.

...

Anti static floor design key points of selection

Anti static floor called conductive floor, because the people walking shoes and the floor friction and static electricity, with the ions in the floor surface of the dust in the air of the attraction, the computer room, electronic factories and other units will cause certain impact. Conductive floor is a floor is electrically conductive, floor contains electrically conductive fiber, the floor in construction under the floor laying copper foil, copper foil to be connected to the underground buried conductor, let the floor to produce electrostatic directly into the earth, but do not have the floor from electrostatic ion, laying on the floor to use conductive glue laying.Anti static floor has 2 kinds, one is the overhead of anti-static floor anti-static floor, two PVC. Overhead anti-static floor is generally applicable to the need for wiring many rooms, such as room, computer room, computer room, control room. PVC anti-static floor, generally used in the wiring less room, such as electronic workshop, production workshop, there are anti-static requirements of the place.For small medium and large computer room, in order to prevent static electricity to the equipment room of the adverse effect, must consider the installation and use of anti-static floor activities. Because it provides a lot of advantages:1 so that the installation is simple, and for the subsequent equipment configuration changes and expanded to provide greater flexibility.In 2 the engine room equipment anti-static floor under free electrical connection, convenient laying and repair, so that the room is neat and beautiful.3 it can protect all kinds of cables, wires, the data line and the socket, so that it is not damaged.4 room can use the space below the floor as air static pressure air base, obtain satisfactory air distribution. Regardless of the installation of computer equipment in what position, are available through the activities of anti-static floor air supply air outlet are.5 of the equipment at the bottom of the repair, maintenance.6 elimination of cables exposed the harm to the human body.7 can use the activities of anti-static floor adjustability to eliminate the ground roughness, the engine room to ensure the overall levelness of the floor.8 can make the static charge leakage to the ground, and the reflection of electromagnetic radiation.

...

raised access floor's Main characteristic

raised access floor has the advantages of light weight, high strength, smooth surface, good dimensional stability, surface texture, and other characteristics of good decorative effect. In addition, there are fire, insect prevention, corrosion resistance and other properties of rat invasion. ( two) use is suitable for the post and telecommunications departments, tertiary institutions, industrial and mining enterprises of electronic computer room, computer room, communications room, microwave carrier automatic telephone exchange room, ground satellite room, laboratory, SPC, control room, radio room, air conditioner for the conference room, living room, office automation, advanced guesthouse, TV communication hub the transmitting station, a military command post and other anti-static requirements of the place. Representatives of manufacturers: Guangzhou China antistatic computer room floor Engineering Company Limited ( three) tectonic activity floor is composed of an adjustable bracket, and the bracket is generally composed of stringers panels, metal, wire rod, aluminum alloy, cast iron or other kinds of high-quality cold-rolled steel plate. Stringer angle steel, zinc plate, high-quality cold-rolled steel plate and other kinds of. The bottom face of the panel is made of aluminum alloy, glass steel is poured into the hollow interlayer, surface by polyester resin adding antistatic agent, fillers made of antistatic plastic overlay; cast aluminum alloy surface adhesive soft plastic; flat pressing of particleboard double-sided with melamine formaldehyde resin decorative plate; or using double-sided stickers plastic wood plywood. A conductive paint edge, in addition to sealing pad and the conductive rubber strips, connecting parts are made of electrically conductive adhesive

...

why Wood floors will ring

The floor exercise ( produces a sound ) for the following reasons:
The 1 surface roughness
Because the surface is not smooth, floor coverings, individual place between the floor and the ground to produce gap, people walk in the process, the floor move up and down, produces a sound. Its characteristic is the floor pavement after, people walking will immediately produce the sound, but also local. Measures are floor pavement before you must first measuring surface roughness, the flatness is less than 3mm / 2000mm, does not have the conditions of ground, should first leveling after the shop.
...
Page:[«]1[2][3][4][5][6][7][8][9][10][11][12][13][14][»]

Powered By Z-Blog

Copyright jeccaccessfloors.com. Some Rights Reserved.